Section 4: Operation
Operator Manual
Doc. No. 101205
4.7
4.1.7 Operating and Changing the Electronic Lock
Before operating the lock or changing the combination,
READ THE INSTRUCTIONS THOROUGHLY
*
.
*See manufacturers lock manual included in the “Open Me First Box”
The LA GARD “LG Basic” series electronic lock uses a
touch key pad for all lock functions.
Power is supplied to the lock via a standard 9-volt
Alkaline battery which contained within the external
portion of the lock. The lock will warn of low voltage by
repeatedly beeping.
TO UNLOCK FROM DEFAULT COMBINATION – ( 1-2-3-4-5-6 )
Step 1
Press the default combination one button at a time, 1, 2, 3, 4, 5, 6. A beep is heard
following each key press.
Step 2
If the combination is entered correctly a double-beep is heard and the internal lock
solenoid will click indicating that the lock is open and the vault handle my now turn.
Step 3
If the wrong combination is entered a triple-beep will be heard. If the correct
combination is not entered within 4 consecutive attempts a 5 minute delay or “lock
out” will begin. During this time, the led at the 2 o’clock position on the face of the
lock will flash at 10 second intervals. In addition any key press will respond with a
triple-beep. Once the 5 minutes has elapsed, 2 more consecutive failed attempts will
restart the 5 minute timer.
END
WARNING:
While orienting yourself with the lock, making changes to the lock
programming (including changing the combination) ALWAYS work with the vault door
open. Do not close the vault until the lock has been thoroughly tested.