72
T23
Series User Manual
For more information about Tramigo tracking products, please visit www.tramigo.com. For distributor, re-seller and
partnership opportunities, email
PanicButtonHoldTime
2
1
3600
s
Required duration of panic button press
PowerButtonHoldTime
2
1
3600
s
Required duration of power button press
ReArmDelay
30
1
900
seconds
Time interval before Alarm is re-armed after pressing
SOS button.
RequireOwnerConfirmation
0
0
1
boolean
If set on the new owner is requested to confirm but
sending owner,yes command.
SensorOff
1
0
1
boolean
Enables sensor off reporting
SensorOn
1
0
1
boolean
Enables sensor on reporting
ShowTime
1
0
1
boolean
Enable time stamps at end of reports
Sleep
1
0
1
boolean
Enable sleep mode
Sleep1GsmOff
0
0
1
boolean
GSM turned off in sleep mode 1
Sleep1OffTime
55
1
9999
min
Off time in sleep mode 1
Sleep1OnTime
5
1
9999
min
On time in sleep mode 1
Sleep1Repeats
6
1
9999
Number of repeats in sleep mode 1
Sleep2GsmOff
1
0
1
boolean
GSM turned off in sleep mode 2
Sleep2OffTime
55
1
9999
min
Off time in sleep mode 2
Sleep2OnTime
5
1
9999
min
On time in sleep mode 2
Sleep2Repeats
120
1
9999
Number of repeats in sleep mode 2
Sleep3GsmOff
1
0
1
boolean
GSM turned off in sleep mode 3
Sleep3OffTime
1435
1
9999
min
Off time in sleep mode 3
Sleep3OnTime
5
1
9999
min
On time in sleep mode 3
Sleep3Repeats
0
1
9999
Number of repeats in sleep mode 3
SleepTimeoutIgnition
60
1
9999
min
Sleep timeout from ignition switched off
SleepTimeoutWake
10
1
9999
min
Sleep timeout from the last wake trigger
SMSRetriesTotal
15
1
99
number
Number of times the T23 Sries will attempt to resend a
SMS.
SMSSendTimeout
1
9999
min
timeout for sending sms
SOSGPIO
0
0
1
boolean
External GPIO input used as a combined SOS/HF
button instead of ignition input
SOSMinPressTime
0
0
999
ms
HF button hold time for SOS detection (for GPIO input)
SOSReportToFriend
0
0
1
boolean
Turn on to include users with Friend authority to SOS
reports.
SpeedLimitFilter
50
1
999
km/h
After a speed limit report, the speed must drop this
much below the limit until more reports are sent
TripEndTime
15
1
999
min
Trip end time
TripStart
1
0
1
boolean
Trip start reports enabled/disabled
TripStartDelay
60
1
999
seconds
Minimum time for a trip report. Trip reports shorter than
this time are ignored
TripStartLockDistance
500
1
9999
m
Distance limit to use previous trip end location as the
new start location
UseIgnition
1
0
1
boolean
Use ignition input (GPIO wired or shock) in vehicle
state handling
VoltageShutdown
3500
3500
5000
mV
Low voltage shutdown limit
VoltageWarning
3650
3501
5000
mV
Low voltage warning limit
VoltageWarningFilter
100
optimum
value
set
mV
After a low voltage report, the voltage must rise this
much above the limit until more reports are sent
WakeOnIgnition
1
0
1
boolean