20
T23
Series User Manual
For more information about Tramigo tracking products, please visit www.tramigo.com. For distributor, re-seller and
partnership opportunities, email
6.2.1
Accelerometer
Important Note:
Version 1.10 and above
Command:
Accelometer,
on/off
Alias:
ACC
Parameters:
on
– optional. Activates the accelerometer
off
– optional. Deactivates the accelerometer
Description:
Observes the acceleration and deceleration, 1 second interval.
Related Cmds:
none
Security:
none
Message Format:
Command Response
Notes:
1.
Reports are generated based on pre-set limits.
2.
Acceleration typical value range is 1.0-2.0 m/s² and for braking it is 0.5-1.5 m/s².
3.
How to change the limits:
a.
‘set,hardaccelerationlimit,19’ - acceleration limit to 1.9 m/s²
b.
‘set,hardbreakinglimit,10’ - braking limit to 1.0 m/s²
Errors:
none
Examples:
ACCELEROMETER,ON
Tramigo: Accelerometer, reporting is turned on, 12:01 Jan 13
ACCELEROMETER,OFF
Tramigo: Accelerometer, reporting is turned off, 13:01 Jan 13