6.2.40
Temperature
Command:
Temperature,on/off/
value
Alias:
TEMP
Parameters:
on/off - turns on or off temperature reporting
value
– optional. Temperature limit
Description:
Sets the MCU temperature reporting on or off, or set the temperature limit
Related Cmds:
none
Security:
Friend
Message Format:
Command Response
Notes:
1.
Can be used to monitor unit temperature.
2.
Temperature report occurs immediately when the internal temperature of the unit exceeds
the limit.
3.
Temperature limits value from 30 C to 100 C, default value is 70 C.
Errors:
1.
Parameter Error
Examples:
TEMPERATURE
TRAMIGO: temperature, limit 70 C, reporting is turned on, 03:43 Oct 23
TEMP,off
TRAMIGO: Temperature, reporting is turned off, 03:42 Oct 23
TEMP,100