![Tramigo T23 Series User Manual Download Page 51](http://html1.mh-extra.com/html/tramigo/t23-series/t23-series_user-manual_1148737051.webp)
51
T23
Series User Manual
For more information about Tramigo tracking products, please visit www.tramigo.com. For distributor, re-seller and
partnership opportunities, email
6.2.30
Report
Command:
Report, userNumber,reportName,on/off/time
Alias:
R
Parameters:
userNumber – required. User number from 1 to 10.
reportName – required. Name of the report to be activated.
on/off – Turns the report on or off, like ALARM
time - Time value for the periodic report, like FIND.
Description:
Allows owners to set the reporting for users.
Related Cmds:
none
Security:
Owner
Message Format:
Command Response
Notes:
1.
The following reports can be controlled: Alarm, Find, Ignition, Trip, Power, Speed, Status,
IdleAlarm and Zone
2.
Parameters can be used for the reports.
3.
Use the ListUser command to determine the user number.
4.
Short forms can be used for the reportName.
Errors:
1.
Lookup Error – report name was incorrect.
2.
User not found Error.
Examples:
To turn on the Alarm report for user 2.
Report,2,A,on
Tramigo: Alarm reporting is turned on for user 2, 23:40 Sep 12
To turn on the Periodic reporting for user 5.
Report,5,F,1
Tramigo: Find reporting is turned on for user 5 (report interval 1.00 km), 04:44 Jun 11
Report,2,F,1,1,60,30
Tramigo: Find reporting is turned on for user 2 (report interval 1 minutes, 1 km, 60