6.2.25
Output
Command:
output,portId,type,commandName,1/0,
time
Alias:
none
Parameters:
portId – Output port ID number
Type – The type of the output port
commandName – The command name for output
1/0 – High or low output
Time – The duration output is on or off
Description:
Configure T23 Series output ports to send signal for accessories
Related Cmds:
None
Security:
Owner
Message Format:
Command Response
Notes:
1.
T23 port Ids are from 1-3.
2.
T23 Fleet and T23 Track port Ids are from 1-2.
3.
Types can be IMMOBILIZER or GENERAL.
Errors:
1.
Parameter error
Examples:
OUTPUT,1,IMMOBILIZER,DISABLE,1,0
Tramigo: Output: 1, type: immobilizer, literal: disable, high: 1, time: 0, 15:37:33 Dec 12
DISABLE,ON
Tramigo: Disable, vehicle ignition disabled, parked, at Valero Street-Rufino Street,
Makati, NCR, PH, 14.55931, 121.01934, 15:39:06 Dec 12
Custom output command:
OUTPUT,2,GENERAL,LIGHTON,1,1000
Tramigo: Output: 2, type: general, literal: LIGHTON, high: 1, time: 1000, 15:40:03 Dec
12
LIGHTON
Tramigo: Output (LIGHTON), turned on for 1000 milliseconds, 15:40:19 Dec 12
Check output port current settings:
OUTPUT,2
Tramigo: Output: 2, type: general, literal: LIGHTON, high: 1, time: 1000, 15:42:06 Dec
12