10.12 Measuring system diagnostics
10.12.1 Object 6500h: Operating status
The object
6500h “Operating status” contains the operating status and informations
about the internal programmed parameters.
Index
0x6500
Description
Operating Status
Data type
UNSIGNED16
Category
Mandatory
Access
ro
PDO mapping
No
Bit
Function
Bit = 0
Bit = 1
0
code sequence
increasing
decreasing
1
reserved
2
scaling parameters are used
-
Yes
3 - 15 reserved
10.12.2 Object 6501h: Single-Turn resolution
The object 6501h contains the number of measuring steps per revolution which can
be output by the measuring system.
Index
0x6501
Description
Singleturn Resolution
Data type
UNSIGNED32
Category
Mandatory
Access
ro
PDO mapping
No
Upper limit
device specific (max. value see nameplate)
Single-Turn resolution
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
Standard value: 4096 = 1000h steps per revolution (depending on capacity marked