8 Operating Modes
Two operating modes are supported by the measuring system:
● Synchronous
● Distributed Clocks
In "Synchronous" operating mode, the process data is output synchronously to the
EtherCAT bus cycle time.
In "Distributed Clocks" operating mode, the process data is output synchronously to a
self-defined time. The relevant settings are made in the EtherCAT master. By the
measuring system the synchronization signals "SYNC0" and "SYNC1" are supported.