Communication-Specific Standard Objects (CiA DS-301)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2010, All Rights Reserved
10/07/2013
TR - ECE - BA - DGB - 0080 - 05
Page 139 of 176
Sub-Index
2
Description
Communication Type Sync Manager 1
Data type
UNSIGNED8
Category
Mandatory
Access
ro
PDO mapping
No
Value
2: Send mailbox (Slave --> Master)
Sub-Index
3
Description
Communication Type Sync Manager 2
Data type
UNSIGNED8
Category
Mandatory
Access
ro
PDO mapping
No
Value
3: not used
Sub-Index
4
Description
Communication Type Sync Manager 3
Data type
UNSIGNED8
Category
Mandatory
Access
ro
PDO mapping
No
Value
4: Process data input (Slave --> Master)