tousek
/ EN_ST-80-M-S_05 / 25. 03. 2020
- 5 -
or
accessories,
max. 0,3A
Technical data
Barrier control
ST 80
ST 80V
ST 80
ST 80V
Power supply
230Va.c. 50Hz
Ambient temperature
- 20°C bis + 70°C
max. permited motor capacity
230Va.c., 500W
Protection class
IP66
Signal lamp output
230Va.c., 100 W max
Speed sensor
Boom lamp output
24Vd.c.
Forced closing
Magnetic clamp output
24Vd.c., 5W max.
Art.no.
Master
12111570
12111580
Photocell output
24Va.c.
Slave
12111550
12111560
Optional equipment
pluggable receiver • additional module for status of barrier • induction loop detector • other
impulse givers and safety equipment
2. Terminal assignment
Barrier control ST 80, ST 80V / Master-Slave
Warning
•
Before taking off the control cover, the
mains switch must be turned off!
•
If the control is power supplied, its inner part is under tension.
•
In order to avoid electrical strokes, the safety regulations have to be
respected.
•
The device may only be connected by trained professionals.
•
The product is not suitable for installation in explosion-hazardous areas.
•
An all-pole disconnecting mains switch with a contact opening gap of
min. 3 mm has to be foreseen. The barrier facility has to be secured
according to the valid safety regulations!
•
IMPORTANT: The control lines (sensor, buttons, radio, photocells, etc.)
have to be laid separately from the 230V lines (supply line, motors,
signal lamp).
L N
boom lamp
24Vd.c.
magnetic clamp
24Vd.c.
I-loop 1
I-loop 2
signal contact “attendance”
ISD-channel-1/-2
grounding
230V
a.c.
Phase
50Hz
zero line
signal lamp 230V
max. 100W
41
42
43
44
45
46
50
52
31
37
32
30
33
30
34
30
54
20
21
22
23
80
81
0
1
2
10
11
L N
LS-transmitter
LS-receiver
8.k2
PHC-contact
contact edge main closing edge
70
71
74
75
9/1
9/2
9/3
9/4
78
79
– + – +
PHC-supply
ST
OP-button
impulse button
CLOSE-button
partial opening button
barrier door contact
connection possibility
for motor condenser
(if not connected yet to the motor !)
Master-control board
Terminal assignment
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!
black (opening)
gray (blue)
brown (closing)
grounding
motor
connection