Manufacturer´s Declaration of conformity:

The company TOUSEK Ges.m.b.H., Zetschegasse 1, 1230 Vienna/Austria, declares that the control unit  

ST 80 (ST 80V) / Master-Slave

 complies with the following direcives:

- Low Voltage Directive 2014/35/EU, incl. changes

- Electromagnetic Compatibility Directive 2014/30/EU, incl. changes

January 2019

 Maintenance

• 

Maintenance works may only be carried out by qualified personnel.

• 

Maintenance and servicing of the complete barrier facility has to be carried out according to the barrier builder´s/

installer´s instructions.

•  Check on a monthly basis whether force adjustment works properly.

 

GENERAL WARNING AND SAFETY NOTES

•  These installation and operating instructions form an integral part of the product “control”. They have been specifically 

written for professional installers trained and skilled in the trade and should be carefully read in their full length before 

carrying out the installation. They describe the proper installation and operation of the control unit only, not of the overall 

device “automatic barrier”. After the installation this manual has to be handed over to the user.

•  Installation, connection, adjustments, putting into operation, and servicing may only be carried out by trained profession-

als in full accordance with these installation- and operating instructions.

•  Before carrying out works at the barrier-system, the power supply has to be turned off.

•  The EU Machine Directive, laws and rules concerning the prevention of accidents, and laws and standards which are in 

force in the EU and in the individual countries have to be strictly followed.

•  The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in 

force during the installation and operation.

•  The packaging materials (cardboard, plastic, EPS foam parts and filling material etc.) have to be properly disposed of 

in accordance with the applying recycling- and environmental procection laws. They may be hazardous to children and 

therefore have to be stored out of children´s reach.

•  The product is not suitable for installation in explosion-hazardous areas.

•  The product may only be used in accordance with its original purpose, for which it has been exclusively designed, and 

which is described in these installation and operating instructions. The TOUSEK Ges.m.b.H. rejects any liability if the 

product is used in any way not fully conforming to its original purpose as stated herein.

•  Children have to be instructed, that the gate facility as well as the belonging parts may not be used improperly, e.g. for 

playing. Furthermore handheld transmitters have to be kept in safe places and other impulse emitters as buttons and 

switches have to be installed out of children‘s reach.

•  Before beginning with the installation the installer has to make sure that all mechanical components of the gate facil-

ity, like carrier profile/rail, gate frame and panels, guiding elements etc. are sufficiently supportive and resistant for the 

purpose of gate automation.

•  All electrical installations have to be made in full conformity with the applying rules and laws (e.g. using a fault current 

circuit breaker, proper grounding etc.).

•  An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be foreseen.

•  The electric motor heats up during operation. Therefore the device should only be touched after it has cooled off.

•  After installation the proper function of the barrier facility and the safety devices has to be checked!

•  The TOUSEK Ges.m.b.H. rejects any liability for claims resulting from usage of the product in combination with compo-

nents or devices which do not fully conform to the applying safety laws and rules.

•  Only original spare- and replacement parts may be used for repair of the product.
•  The installer has to inform the user about all aspects of the automatic operation of the complete barrier facility, as well as 

about emergency operation. The installer further has to supply to the user all instructions relating to the safe operation 

of the barrier facility. The installation and operating instructions also have to be handed over to the user.

Summary of Contents for ST 80

Page 1: ...Installation and connection manual Barrier control ST 80 ST 80V Master Slave combination for double barrier...

Page 2: ...he manual replaces all earlier publications of the same Index General warning and safety details 3 1 Notes general characteristics control board layout technical data 4 5 2 Terminal assignment 5 7 3 P...

Page 3: ...They may be hazardous to children and therefore have to be stored out of children s reach The product is not suitable for installation in explosion hazardous areas The product may only be used in acc...

Page 4: ...mmingwithilluminatedLCdisplayinenglischlanguage Three operating modes impulse automatic deadman Automatic closing with adjustable pause time Runtime of operator is being automatically determined Separ...

Page 5: ...plosion hazardousareas An all pole disconnecting mains switch with a contact opening gap of min 3 mm has to be foreseen The barrier facility has to be secured according to the valid safety regulations...

Page 6: ...ns switch with a contact opening gap of min 3 mm has to be foreseen The barrier facility has to be secured according to the valid safety regulations IMPORTANT The control lines sensor buttons radio ph...

Page 7: ...l with slave control the terminals 88 and 89 of system plugs of each control have to be connected with each other see picture below Important max cable length between the barrier housings is 25m Cable...

Page 8: ...the shown value of a parameter is given When pressing the button you return to the superior menu point Possibly changed adjustments of a parameter are rejected with this button the former values will...

Page 9: ...with pause time extension M motor partial opening Master Slave M G operating mode impulse mode automatic 1 255s increment 1 M pause time logic no influence constant open in automatic mode M forced clo...

Page 10: ...r boom stops If deadman mode is selected the radio receiver is set out of order for safety reasons If the impulse switch is set to DEAD MAN operation then the partial opening switch works the same way...

Page 11: ...Note if the function open under menu point is selected and if the impulse switch is set to DEADMAN then the opening of the boom is omitted when driving over the I loop 9 1 9 2 9 3 9 4 I loop 1 I loop...

Page 12: ...two pairs of photocells please do not install both photocell transmitters receivers on the same side to eleminate interference between both Exception photocells with SYNC function allow the installati...

Page 13: ...J 2 photocells Tousek LS 41 LS 180 as safety device with SYNC function activated N O COM N C J J N O COM N C transmitter 1 receiver 1 transmitter 2 receiver 2 41 42 43 44 45 46 SYNC J Important As the...

Page 14: ...sing command has to be actuated Stop during closing then close an interruption of the photocell beam or induction loop during closing makes the motor stop as long as the photocell loop stays interrupt...

Page 15: ...barrier G Operating mode M Operating logic Impulse mode Impulse through impulse switch button or CLOSE button to start closing of barrier Automatic mode pause time 1 255s adjustable increment 1 barri...

Page 16: ...rd the setting is made via Master control Prewarning OPEN signal lamp terminals M S 10 11 M Light lamps turned off 1 30s adjustable Before each opening movement the signal lamp flashing light is activ...

Page 17: ...ay attention to polarity 70 71 74 75 9 1 9 2 9 3 9 4 78 79 R Magnet fix 24V Signal contacts M Peripherals Status display 1 with the two potential free signal contacts K1 and K2 the adjustments of the...

Page 18: ...are newly set after an impulse Software version control function M S Reset Diagnosis shows the software version on display Serial number control function M S Reset Diagnosis shows the serial number o...

Page 19: ...can be made easily with the rotary switches D1 for channel 1 and D2 for channel 2 as well a s the DIP switches DIP see corresponding manual Factory settings DIP1 DIP8 OFF D1 and D2 4 DIP DIP switch RE...

Page 20: ...eiver please see manual for radio receiver Turn off power supply Open cover of control unit Receiver board E RS433 868 STN1 1 channel or RS433 868 STN2 2 channel into the connection slot FE as shown i...

Page 21: ...aster control Exit using ESC button system tests of the master control are carried out If an error occurs you get into the BASIC SETTINGS again by pressing the ENTER button After the successfull syste...

Page 22: ...utton for 5s from any position in menu Master control M Putting into operation BASIC SETTING of Master control For setting the most important adjustments for initial operation of motor Can be selected...

Page 23: ...gered This would lead to an interruption of the programming process Operation mode Operation mode impulse mode Operation mode aut close 5s Operation mode aut close 10s System test Photocell System tes...

Page 24: ...status dispaly for help Display Low Voltage undervoltage check supply line Display search Master communication problem check connection transmission Display search Slave communication problem check co...

Page 25: ...05 25 03 2020 25 240 195 depth 105 9 Dimensioned drawing of box IP54 Barrier control ST 80 ST 80V Master Slave dimensions in mm We reserve the right to change dimensions and technical specifications w...

Page 26: ...used All shear crush and pinch points of the door system must be protected absolutely In this context we refer to the Machinery Directive and safety regulations and EU standards in their country or as...

Page 27: ......

Page 28: ...Gliwicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 252 61 Jene u Prahy Pr myslov 499 Tel 420 777 751 730 info tousek cz We reserve the right to change di...

Reviews: