INTERFACE MANUAL
Designation
ALM_RST (Alarm reset)
Input terminal
CN5–31 pin
Exclusive signal
name used in the
controller
254
Signal logic
Signal judgment
Signal terminal
ON OFF
Open
O
Short-circuit O
Function
Used to cancel an alarm from the external equipment, which
occurred while the TS2000/TS2100 robot controller was ready
to start.
This signal can be used only in the EXT. SIGNAL mode.
Signal timing
SYS_RDY (O)
ALARM (O)
ALM_RST (O)
Cautions
If an alarm of the emergency stop level which will not allow the
processing of EX_SVON, or EMSST_A ~ EMSST_B is output,
alarm reset by the ALM_RST signal is not possible.
STE 71367
– 49 –