STE 73995
– 55 –
TRANSPORTATION AND INSTALLATION MANUAL
4.2.1 Controller's Tool Signals
The controller is provided with tool signals (i.e., five (5) input signals for sensor, etc.,
four (4) control signals for solenoid valve, etc., DC 24V and DC 24 VGND signals),
which can be connected also from the controller side. (A cable between the controller
and cable is an option.) The relevant signals are described below.
a) Input signal connector HAND
Table 4.1 Input signals
Pin
Signal name
Signal No.
Input circuit and example of
connections
1
HI_2
Hand input 1
201
8
HI_2
Hand input 2
202
2
HI_3
Hand input 3
203
9
HI_4
Hand input 4
204
3
HI_5
Hand input 5
205
10 P24V
24 V
4 P24G
0
V
11 HI_COM1 Common
-
11
Customer's side
-
1
-
8
-
2
-
9
-
3
●
●
Power supply
As input signals, no-voltage contacts or transistor open collector inputs are used.
No-voltage contact specifications:
Contact rating: DC24 V, 10 mA or over (circuit current: approx. 7 mA)
Minimum contact current: DC24 V, 1 mA
Contact impedance: 100
Ω
or less
Transistor
specifications:
Withhold voltage between collector and emitter: 30 V or over
Current between collector and emitter: 10 mA or over (circuit current: approx. 7
mA)
Leak current between collector and emitter: 100 µA or less