2 - 8
710CDT/720CDT
❑
B12V Output
Error code
Meaning
40h
B12V voltage is over the maximum allowed limit.
41h
B12V voltage is below the minimum allowed limit.
42h
B12V does not start when the power supply is turned on.
43h
B12V is below the minimum allowed limit during suspend.
❑
Power supply microcontroller
Error code
Meaning
50h
Firmware or program error.
❑
Environmental condition
Error code
Meaning
80h
CPU temperature is outside the allowable range.
88h
The CPU overheats, the system enters resume mode and
automatically shuts down.
Check 2
If error code 01h displays:
❑
Make sure the AC adapter and AC power cord are firmly plugged into the
DC IN 15 V socket and wall outlet. If these cables are connected correctly,
go to the following step:
❑
Connect a new AC adapter. If the error still exists, go to Procedure 5.
Check 3
In error code 02h displays:
❑
Make sure the Desk Station V Plus is firmly connected to the computer's
docking interface port. If this port is connected correctly, go to the follow-
ing step:
❑
Visually check the connector to make sure that no pins are bent. If a pin(s) is
bent, go to
Chapter 4
,
Replacement Procedures
. If the connector is not
physically damaged, go to the following step:
❑
Check the Desk Station V Plus for malfunctions. Refer to the
Desk Station V
Plus
maintenance manual for details. If the error still exists, go to
Procedure 5.