710CDT/720CDT
3 - 5
NOTE: The menu displayed by your computer may different slightly from the
one shown above.
4.
Select the desired subtest from the subtest menu and press
Enter
. The following
messages will display:
TEST LOOP
: YES
ERROR STOP
: YES
Use the arrow keys to move the cursor to the desired option and press
Enter
.
Selecting
YES
for
TEST LOOP
sets the test to run continuously until it is halted by
the user. Selecting
NO
returns the screen to the main menu after the test is
complete.
Selecting
YES
for
ERROR LOOP
stops the test program when an error is found and
displays the operation guide on the right side of the display screen as shown below:
ERROR STATUS NAME [[ HALT OPERATION ]]
1: Test end
2: Continue
3: Retry
These three selections have the following functions:
1:
Terminates the test program and exits to the subtest menu.
2:
Continues the test.
3:
Restarts the test from the error.
Use the arrow keys to move the cursor to the desired option and press
Enter
.
Selecting
NO
for
ERROR STOP
keeps the test running even if an error is found.
Table 3-1 in Section 3.3 lists the function of each test on the subtest menu. Table 3-2 in
Section 3.18 lists the error codes and error status for each error.