710CDT/720CDT
2-25
Check 2
Using the Diagnostic Disk, format the HDD with a low level format option. Refer
to
Chapter 3
,
Tests and Diagnostics
for more information about the diagnostic
program.
If the following message appears on the display, the HDD low level format is
complete: "Format Complete".
Partition and format the HDD using the MS-DOS FORMAT command. If you
cannot format the HDD using the Tests and Diagnostic program, go to Procedure 4.
Procedure 4
Diagnostic Test Program Execution Check
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the
Hard Disk Drive Test. Refer to
Chapter 3
,
Tests and Diagnostics
, for more information about
the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed. In this
case, perform Check 1. Error codes and their status are described in Table 2-6. If an error
code is not generated, the HDD is operating properly.
Table 2-6 Hard disk drive error code and status
Code
Status
01h
Bad command
02h
Bad address mark
04h
Record not found
05h
HDC not reset
07h
Drive not initialize
08h
HDC overrun (DRQ)
09h
DMA boundary error
0Ah
Bad sector error
0Bh
Bad track error
10h
ECC error
11h
ECC recover enable
20h
HDC error
40h
Seek error
80h
Time out error
AAh
Drive not ready
BBh
Undefined error
CCh
Write fault
E0h
Status error
EEh
Access time out error
FFh
Data compare error
Summary of Contents for Tecra 710CDT
Page 187: ...B 2 710CDT 720CDT B 2 System Board Back View Figure B 2 System board layout back ...
Page 207: ...C 16 710CDT 720CDT ...
Page 221: ...G 2 710CDT 720CDT ...
Page 222: ...710CDT 720CDT G 3 ...