4 Replacement Procedures
PORTÉGÉ Z930/Satellite Z930 Maintenance Manual (960-887)
[CONFIDENTIAL]
4-45
Installing the Touch pad/Fingerprint sensor board
To install the touch pad/fingerprint sensor board, follow the steps below and refer to Figure
4-18 to 4-21.
1.
Slide the
TP board
to the
hole
of the cover assembly and secure it with the following
screws
.
M2
3B S-THIN
HEAD
2
2.
Stick the
insulator
(INSU SQUARE) to a new fingerprint sensor board in place.
NOTE: Stick the insulator (INSU SQUARE) to the fingerprint sensor board in place as
shown in the figure below.