Tests and Diagnostics
PORTÉGÉ Z930/Satellite Z930 Series Maintenance Manual (960-887)
[CONFIDENTIAL] 3-81
3.29.2
Modem test : (Not Used)
For this subtest, connect the modem PCB and RJ11 connector with a harness. Use the
dedicated “FAT-MODE inspection device (product code: QE2000P01 made by Nitto Denki
Seisakusyo)” for the tests.
##################################################################
###### AC97' Modem Controller Diagnostics program #######
##################################################################
*
*
*
1 ............ (ICHx)
*
*
*
*
2
............
(ICH6)
*
*
*
******************************************************************
.... Press test number[1-2] ?
To execute Modem test, press
2
and
Enter
. Following message will appear:
[Modem loopback test !]
ICHx MDC Test Program with Modem Sound (Line Test)
Version X.X
* Scorpio Modem Initialize
:OK
* Digital Loopback Test
:OK
* RJ11 Connector Check (LED)
:(Operator’s Check!!)
OK
is displayed when a error is detected,
NG
is display when a error is not detected.
NOTE: The menu displayed by your computer may be slightly different from the one
shown above.
RJ11 Connection Check (LED) (Operator’s Check LED) test will be executed, and the
following message will appear:
...Press Key (Y = OK , N =NG)
If the color in the LED of the connection checker is orange, press
Y
,
otherwise, press
N
.