3.2 Setup Registers
MW Register Allocation Table :
Module
MW Range
Total No Supported
Base
MW0000-MW0059
60
Expansion Slot 1
MW0100-MW0123
24
Expansion Slot 2
MW0200-MW0223
24
Expansion Slot 3
MW0300-MW0323
24
Expansion Slot 4
MW0400-MW0423
24
Expansion Slot 5
MW0500-MW0523
24
Setup Registers for Fixed I/O OIS PLUS
For discrete inputs, the MW registers are used for setting up the high speed counter. The discrete
inputs on the fixed I/O OIS and the discrete inputs on the clip-on modules can be setup as 2 discrete
high speed inputs or 1 quadrature input.
MW Type
Local CH1
Local CH2
HSC Configuration register
MW0010
MW0020
High Speed Counter (HSC) Register
MW0011
MW0012
MW0021
MW0022
HSC Preset Register
MW0013
MW0014
MW0023
MW0024
HSC Enable Bit
MW0015_0
(M00240)
MW0025_0
(M00400)
HSC Reset Bit
MW0015_1
(M00241)
MW0025_1
(M00401)
These are default system tags created when a fixed I/O OIS PLUS is selected.