46
H9 ASD Installation and Operation Manual
Program Mode Menu Navigation
The following table lists the menu items of the Program mode and maps the flow of the menu selections.
The Parameter Numbers for the listed functions are provided where applicable.
The functions listed may be accessed (and changed) as mapped below or via the Direct Access method:
Program
⇒
Direct Access
⇒
Applicable Parameter Number.
Program Mode Menu Navigation
Primary Menu
Sub Menu
Parameter Name
Parameter
Number
S
TARUP
W
IZARD
See the section titled
Initial Setup on pg. 70
for Startup Wizard Requirements.
F
UNDAMENTAL
Fundamental
Accel/Decel #1
Settings
Automatic Acceleration/Deceleration
F000
Acceleration Time 1
F009
Deceleration Time 1
F010
Acceleration/Deceleration Suspended Function
F349
Acceleration Suspend Frequency
F350
Acceleration Suspend Time
F351
Deceleration Suspend Frequency
F352
Deceleration Suspend Time
F353
Frequency Settings
Maximum Frequency
F011
Upper Limit Frequency
F012
Lower Limit Frequency
F013
V/f Pattern
F015
Time Limit for Lower Limit Frequency Operation
F256
Motor Set #1
Automatic Torque Boost
F001
Base Frequency 1
F014
Manual Torque Boost 1
F016
Motor Overload Protection Level 1
F600
Standard Mode
Selection
Command Mode
F003
Frequency Mode 1
F004
Forward/Reverse Run
F008
Frequency Priority
F200
Frequency Mode 2
F207
Frequency Mode Priority Switching Frequency
F208
FM Output Terminal Function
F005
FM Output Terminal Adjustment
F006
rogram