34
H9 ASD Installation and Operation Manual
Keypad Remote Mounting w/o the ASD-MTG-KIT
Note:
See
Figure 25
for the dimensions and the item locations referenced in steps
1
through
5
.
1.
At the keypad mounting location, mark the 3.80” by 3.56” hole and the four 7/32” screw holes.
2.
Cut the 3.80” by 3.56” rectangular hole.
3.
Drill the four 7/32” screw holes.
4.
Attach and secure the EOI to the front side of the mounting location using the four 6-32 x 5/16” pan
head screws, the #6 split lock washers, and the #6 flat washers.
5.
Connect the extension cable.
Keypad Dimensions (mounting)
Figure 25. Keypad Mounting Dimensions.