5
Monobloc Outdoor Unit Installation Manual
3.0
Preparation for Installation
Parts required to connect this product (Common items)
Category
Part
Specification
Quantity
Water piping
Strainer (water filter)*
1.2mm mesh
1
Drain cock
For water charge
1
Isolating ball valves
Inlet: 1 1/4” ** or 1” ***
Outlet: 1”
2
Electrical system
Earth leakage breaker for main power
supply
30mA
1
Earth leakage breaker for auxiliary
power supplies
30mA
Depends on
system setup
Note: *
Included with hydronic module option
** Diameter with hydronic module option
*** Diameter without hydronic module option
Options required for each function
Function
Accessory / Option
Field Supply
Cooling
-
Fan coil (s)
-
Under floor cooling
-
Under floor safety thermostat
Heating
-
Radiators
-
Fan coil (s)
-
Under floor heating
-
Under floor safety thermostat
Heating & cooling
(all rooms)
-
Fan coil (s)
-
Under floor cooling / heating
Heating & cooling
(part heating only)
-
Motorised 2 way valve
-
Relay & Earth leakage breaker (2WV)
Hot water supply
Estia DHW cylinder (includes
DHW Heater & DHW sensor)
Motorised 3 way valve
Relay & Earth leakage breaker (3WV)
Relay & Earth leakage breaker (DHW Heater)
Domestic hot water sensor
Field supply DHW Cylinder (includes DHW Heater)
Motorised 3 way valve
Relay & Earth leakage breaker (3WV)
Relay & Earth leakage breaker (DHW Heater)