35
Monobloc Outdoor Unit Installation Manual
Boiler ON/OFF DHW cylinder heater connection (optional)
Depending on the configuration, it is possible to control up to three electric heaters or three electric heat stages
i) One electric heat stage with one customized discrete output: EH1
ii) Two electric heat stages with two customized discrete outputs: EH1 and EH2
iii) Three electric heat stages with two customized discrete outputs: EH1 and EH2
iv) Three electric heat stages* with three customized discrete outputs: EH1 and EH2 and EH3.
*
This configuration cannot be activated if DHW heater is present.
The boiler ON/OFF and the stage 1 electric heater use the same output. It is not possible to operate the boiler ON/
OFF and the stage 1 electric heater at the same time.
Each discrete output can control a contactor (not supplied with the unit).
7.8.13 External electrical connections – digital outputs (230VAC relay)
Function
Description
DO#01
Main water pump ON/OFF
DO#03
Additional water pump ON/OFF
DO#04
No function (future development)
Relay
Out 230 VAC - 5 A
Unused
Additional WP On/Off (fixed speed)
Main Water Pump On/Off
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral
T>
Tmax.
QS