48
Monobloc Outdoor Unit Installation Manual
Par.
JBus Addr
Mnemonic
Description
Range
Unit
RC
JBus
423
01A7H
htecooff
Heat Away Offset (Air)
-10.0 to 0.0
1/10 K
RW
RW
424
01A8H
cloccstp
Cool Home Setpoint (Air)
20.0 to 38.0
1/10°C
RW
RW
425
01A9H
clunooff
Cool Sleep Offset (Air)
0.0 to 10.0
1/10 K
RW
RW
426
01AAH
clecooff
Cool Away Offset (Air)
0.0 to 10.0
1/10 K
RW
RW
427
01ABH
freezstp
Home AntiFreeze Setpoint
6.0 to 12.0
1/10°C
RW
RW
646
0286H
jbus_bdr
Secondary Baud Rate
0 to 2 [9600/19200/38400]
-
RW
RW
761
02F9H
jbus_ena
JBus Control Enable
0 to 3
-
RW
RW
762
02FAH
jbus_add
JBus Follower Address
1 to 255
-
RW
RW
764
02FCH
jbus_frm
JBus Frame Type
0 to 5
-
RW
RW
766
02FEH
jbus_tmt
JBus Comm. Timeout
0 to 600
s
RW
RW
Legend:
No No access
RO Read-Only
RW Read/Write
RO/d Read-Only and Display on the RC
RO/F Read-Only and Parameter Forcing