4.e-Filing-specific Adjustments
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
4-7
4.4
To Scan and Print, while Minimizing Moiré
Explanation
An original is scanned and stored in the e-Filing box (Scan to Box). When the image stored is printed
directly from the e-Filing box, moiré may occur, depending on the type of original. Also, it is likely to
occur, particularly when the original is scanned in the Full color mode or the Auto Color mode in a high
resolution (600 dpi) or even in the Gray scale mode. Select an appropriate scan resolution or adjust the
sharpness intensity in the scanning functions, in order to store the original and print it from the e-Filing
box, while minimizing moiré.
Procedures
• You can start with any of the procedures. But it is recommended to perform the procedures in order, as
listed below. You can perform one procedure in conjunction with another. But if this changes the image
quality more than required or loses the effectiveness of the adjustment, restore the settings made in
the previously performed procedure to the original ones. Then perform other procedures.
• Both the service technician and the user can perform procedures (1) to (3).
• Only the service technician must perform procedure (4).
(1) When scanning the original, press [Scan Setting] on the Control Panel. Select “Photo” from among
the original mode options.
• This adjustment will be effective, only if “Text” or “Text/Photo” is initially selected from among the
original mode options.
• This adjustment will have an effect only on the image stored in the Full color mode (including the
Auto color mode).
After changing the original mode, scan and store the original. Then print and check the print image quality.
If further image quality adjustments are still necessary, perform other procedures.
Before adjustment
After adjustment
When the image stored in the e-Filing box
is printed, moiré is likely to occur.
The image stored in the e-Filing box can
be printed, while moiré is minimized.
Scan to Box