1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
1-9
Code setting values
• Decreasing the value will make the solid colored area become lighter (decrease the amount of
toner on the solid colored area). On the other hand, increasing the value will make the solid
colored area become darker (increase the amount of toner on the area).
(b) Select [05 ADJUSTMENT MODE], select code [2742], and then press the [START] button.
After the image quality control is finished, perform printing to check the image quality of the
solid colored area.
• The changed setting values for 08-2513/2514 will be effective for the image printed
immediately after the change. When these values are changed, performing image quality
control with 05-2742 is recommended.
Repeat procedures (a) to (b) as required in order to change the setting value so that the solid
colored area becomes your desired density.
Since the density of a gradation area (Low/Middle density), such as a photograph, is adjusted as
well as that of a solid colored image, follow the procedure below.
Caution after the adjustment
• The adjustment may possibly cause extremely dark images (decreased resolving power and lack of
gradation reproducibility) and extremely light images (blurred images and faint thin lines). Therefore,
perform adjustment carefully while checking the copy or print image.
• Depending on the installation environment of the MFP, the effects of adjustment may not appear.
Therefore, perform adjustment carefully while checking the copy or print image.
Remarks
• The effects of adjustment may vary, depending on the usage pattern of the consumables, such as the
developer material and drum, and the installation environment of the MFP.
• When replacing any consumables, refer to the relevant information in the Service Manual.
Value
Correction value for developer bias
output
Density of the solid colored area
0
Value automatically set −100
Light
1
Value automatically set −80
2
Value automatically set −60
3
Value automatically set −40
4
Value automatically set −20
5
Value automatically set
Default
6
Value automatically set +20
7
Value automatically set +40
8
Value automatically set +60
9
Value automatically set +80
10
Value automatically set +100
Dark
Summary of Contents for e-STUDIO2010AC