5
Outdoor unit
47
(*1) Rated conditions
Cooling: Indoor air temperature 80 °F DryBulb/67 °F WetBulb, Outdoor air temperature 95 °F DryBulb
Heating: Indoor air temperature 70 °F DryBulb, Outdoor air temperature 47 °F DryBulb/43 °F WetBulb
072, 096 type: Equivalent piping length: 50 ft, Height difference: 0 ft, 114 type: Equivalent piping length: 75 ft, Height difference: 0 ft
(*2) Value for only outdoor unit
(*3) Setting is necessary
(*4) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*5) High-pressure switch / High-pressure sensor / Low-pressure sensor / Fusible plug / PC board fuse / Inverter overload protector
(*6) Select wire size based on the larger value of MCA.
MCA: Minimum Circuit Amps (minimum circuit Amps required for power supply design.)
(*7) MOCP: Maximum Overcurrent Protection (Amps)
(*8) This specification is value as of June, 2013, please note that specification is subject to change without notice.
5-1-2. Heat pump
5-1-2-1. 208/230 V model
Single unit (System with Non-ducted indoor units)
Outdoor unit model name
MMY-
MAP0724HT9UL
MAP0964HT9UL
MAP1144HT9UL
Power Supply
Nominal voltage
V/Ph/Hz
(208 / 230) / 3 / 60
Voltage range
V
187 Minimum / 253 Maximum
Cooling
Nominal capacity
(*1)
kBtu/h
72 96
114
Rated capacity
69
92
114
Rated power consumption
(*2)
kW
6.10
8.11
10.16
Rated EER
Btu/W
11.3
11.3
11.2
Heating
Nominal capacity
(*1)
kBtu/h
81 108 128
Rated capacity
81
108
128
Rated power consumption
(*2)
kW
6.68
9.44
11.01
Rated COP
W/W
3.55
3.35
3.41
Starting Current
A
Soft Start
Dimension
Packing
Height
In
76.3 76.3 76.3
Width
In
41.8 50.5 50.5
Depth
In
32.6 32.6 32.6
Unit
Height
In
72.9 72.9 72.9
Width
In
39.0 47.6 47.6
Depth
In
30.7 30.7 30.7
Total Weight
Packed
lbs
579
779
779
Unit
lbs
546
742
742
Color
Silky shade (Munsell 1Y8.5/0.5)
Compressor
Type
Hermetic twin rotary compressor
Motor output
kW
2.3 × 2
2.1 × 3
2.5 × 3
Fan unit
Fan
Propeller fan
Motor output
kW
1.0
1.0
1.0
Air volume
cfm
5,800
6,600
7,060
Maximum external static pressure
(*3) In WG
0.20
0.20
0.20
Heat exchanger
Finned tube
Refrigerant
Name
R410A
Charged refrigerant amount
(*4)
lbs
25.4
25.4
25.4
High-pressure switch
psi
OFF: 420 ON: 540
Protective devices
(*5)
Electrical
specifications
Unit
MCA
(*6)
A
36
50
52
MOCP
(*7)
A
40
60
60
Refrigerant
piping
Liquid
Type
Flare connection
Diameter
In
1/2"
1/2"
1/2"
Suction
gas
Type
Brazing connection
Diameter
In
7/8"
7/8"
1-1/8"
Balance
Type
Flare connection
Diameter
In
3/8"
3/8"
3/8"
Indoor units
Maximum capacity of combined indoor units
80 to 125%
Maximum number of indoor units
12
16
19
Operation temperature range
Cooling FDB
23
to
115
Heating
FWB
-4 to 60
Sound pressure level
Cooling
dB(A)
56.0
60.0
62.0
Heating
dB(A)
57.0
62.0
63.0
Summary of Contents for Carrier MMC-AP0181H2UL
Page 61: ...5 Outdoor unit 60 Model MMY MAP0964HT9UL MAP0964HT6UL MMY MAP1144HT9UL MAP1144HT6UL 72 9 ...
Page 76: ...5 Outdoor unit 75 Model MMY MAP0724FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 77: ...5 Outdoor unit 76 Model MMY MAP0964FT9UL MAP1204FT9UL 208 230 V 60 Hz ...
Page 78: ...5 Outdoor unit 77 Model MMY MAP0964FT6UL MAP1204FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 79: ...5 Outdoor unit 78 5 6 2 Heat pump Model MMY MAP0724HT9UL ...
Page 80: ...5 Outdoor unit 79 Model MMY MAP0724HT6UL ...
Page 81: ...5 Outdoor unit 80 Model MMY MAP0964HT9UL MAP1144HT9UL ...
Page 82: ...5 Outdoor unit 81 Model MMY MAP0964HT6UL MAP1144HT6UL ...
Page 212: ...MEMO ...
Page 213: ...Engineering Data Book For North America August 2015 First Edition ...