6
Indoor unit
128
2.
Dimensions
MMU-AP0071MH2UL, AP0091MH2UL, AP0121MH2UL, AP0151MH2UL, AP0181MH2UL
22.6"(575) Unit external dimension
8.1"(207)
2.5"
(64)
2.5"
(64)
6.9"(175)
1.1"
(29)
5.5"(142)
14.5"(368.5)
20.1"(510) Hanging bolt pitch
7.0"(177)
27.6"(700) Panel external dimension
27.6"(700) Panel external dimension
Electric
parts box
5.8"(148)
1.7"(42)
3.8"(97.5)
5.5"(139.5)
7.5"(190.5)
13.1"(331.5)
20.7"(525) Hanging bolt pitch
Drain Socket(ABS)
8.7"(220.5)
10.6"(268)
1.1"
(27)
5.9"(149)
12.6"(320.5)
23.4" to 26"(595 to 660) Ceiling open dimension
23.4" to 26"(595 to 660) Ceiling open dimension
Ceiling bottom surface
Ceiling bottom surface
(Liquid) 1/4"(6.4)
connecting port
Refrigerant pipe
(Gas) A
connecting port
Refrigerant pipe
Hanging bolt 3/8"(M10)
(To be procured locally)
Ceiling bottom
surface
Ceiling panel
(Sold separately)
Knockout for simple OA
3.9"(100)
For
Hole for power
supply cable
Conduit hole(Knockout)
Hole for remote
controller wires
Ceiling
bottom
surface
Ceiling panel
Indoor unit
0.9''(23)
7''(178)
1.3''(32)
2.1"
(53)
1.4"
(35)
22.6"(575) Unit external dimension
39.4"(1000)
or more
0.6"(15) or more
39.4"(1000)
or more
Space required for installation
39.4"(1000)
or more
0.6"(15) or more
7.9"
(200)
Check port
( 17.7"(450))
23.4" to 26"(595 to 660) Ceiling open dimension
23.4" to 26"(595 to 660) Ceiling open dimension
24.7"
(627.5)
or less
Stand-up
33.5"(850) or less
11.8"(300)
Stand-up
Note)
As ABS is used for the
drain discharge port of
the main unit, the vinyl
chlor paste cannot be
used.
Use the flexible hose
(Band fix) included in the
package.
Drain-up standing-up size
Indoor unit
Ceiling bottom
surface
Unit:in(mm)
Model
MMU-
A
AP007, 009, 012 Type
3/8" (9.5)
AP015, 018 Type
1/2" (12.7)
Summary of Contents for Carrier MMC-AP0181H2UL
Page 61: ...5 Outdoor unit 60 Model MMY MAP0964HT9UL MAP0964HT6UL MMY MAP1144HT9UL MAP1144HT6UL 72 9 ...
Page 76: ...5 Outdoor unit 75 Model MMY MAP0724FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 77: ...5 Outdoor unit 76 Model MMY MAP0964FT9UL MAP1204FT9UL 208 230 V 60 Hz ...
Page 78: ...5 Outdoor unit 77 Model MMY MAP0964FT6UL MAP1204FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 79: ...5 Outdoor unit 78 5 6 2 Heat pump Model MMY MAP0724HT9UL ...
Page 80: ...5 Outdoor unit 79 Model MMY MAP0724HT6UL ...
Page 81: ...5 Outdoor unit 80 Model MMY MAP0964HT9UL MAP1144HT9UL ...
Page 82: ...5 Outdoor unit 81 Model MMY MAP0964HT6UL MAP1144HT6UL ...
Page 212: ...MEMO ...
Page 213: ...Engineering Data Book For North America August 2015 First Edition ...