6
Indoor unit
179
2.
Dimensions
MMD-AP0304H2UL, AP0364H2UL
MMD-AP0484H2UL
4- 0.5"(12) x 3.6"(92)
(Gas side 5/8"(15.9))
(Liquid side 3/8"(9.5))
27.6"(700)
Hole for hanging bolt
Refrigerant pipe connecting port
26"(660)
29.1"(740)
3.
4"
(8
7
)
(73
)
Air suction port
Drain pipe connecting port(VP25)
1.2"
(3
0
)
1.6"
(4
0
)
15"
(3
8
0
)
Refrigerant pipe connecting port
3.
5"
(9
0
)
(110)
2.4"(60)
4.1"(105)
20.7"(526)
3
1
.5
"(
800)
3.1"
(8
0
)
3
.1
"(80)
0
.8
"(20)
1
"(
25)
1"
(2
5
)
0.8"
(2
0
)
(Hangi
ng
bol
t
m
ou
n
ti
n
g
p
it
c
h
)
(Hanging bolt mounting pitch)
33.5"(850)
(Male screw)
4.3"
(1
54
)
6"
8
"(
2
02)
1
"(
25)
Flange
Entering of power supply
and communication wires
1.4"
(3
5
)
1.6"(40)
4.
7"
(1
2
0
)
(87)
26.5"(672)
Air discharge port
Flange
3.4"
(163)
6.4"
2.
3
"
(59
)
11.5"
(2
9
2
)
(30
)
1.
2
"
Unit external dimension
Unit external dimension
2.9
"
3.8"(96)
1"(25)
1"(25)
Electrical
control box
41
.7
"(
10
6
0
)
26"(660)
47.2"(1200)
8.3"(212)
(8
7
)
15
"(
38
0
)
(60)
(105)
1.
6"
(4
0
)
3.
5"
(9
0
)
1
.4
"(
35)
1.
2"
(3
0
)
(110)
Air suction port
Air discharge port
Drain pipe connecting port(VP25)
(Gas side 5/8"(15.9))
Refrigerant pipe connecting port
(Liquid side
3/8"(9.5))
Refrigerant pipe connecting port
Hole for hanging bolt
(Hanging bolt mounting pitch)
(H
an
gi
ng
b
ol
t
mo
un
ti
ng
p
it
c
h
)
(Male screw)
(154
)
6"
8"
(2
02
)
1"
(2
5
)
4- 0.5"(12) x 3.6"(92)
3
.1
"(
80)
0
.8
"(
20)
2.
8"
(7
0
)
3.
1"
(8
0
)
0.
8"
(2
0
)
2.
8"
(7
0
)
27.6"(700)
29.1"(740)
4.3"
3.
4
"
2.4"
4.1"
30.4"(772)
34.5"(876)
2.
3
"
(5
9)
1
1.
5"
(2
92)
(3
0)
1.
2
"
(163)
6.4"
Flange
Flange
1.6"(40)
4.
7"
(1
20
)
Entering of power supply
and communication wires
Unit external dimension
Unit external dimension
3.8"(96)
2.
9
"
(7
3
)
1"(25)
1"(25)
Electrical
control box
or
m
or
e
Service
23.6"(600)
Check port
7.
9"
(2
0
0
)
(5
00
)
Service
or
m
or
e
3
1
.5
"(
800)
19
.7
"
space
space
Distance from building
Check port
Space required for installation or service work
5
.9
"(
150)
or
m
or
e
(Check and cleaning port)
Attention
Be sure to set the plug and to make it to be able to cleaning,
because garbage in drain piping piles up easily in drain trap.
2"
(5
0
)
Plug
Check panel
3.
9"
(1
0
0
)
or
m
or
e
or
m
or
e
<Note>
1. Indoor unit does not have air filter its inside.
So be sure to set an air filter (local
arrangements) in the position maintained
easily such as a air intake grille.
(If there is no air filter, dusts are blocked in the
air heat exchanger and it may cause failure or
water leak in air-conditioner.)
2. Leave sufficient space to remove the air filter
when you attach it.
Summary of Contents for Carrier MMC-AP0181H2UL
Page 61: ...5 Outdoor unit 60 Model MMY MAP0964HT9UL MAP0964HT6UL MMY MAP1144HT9UL MAP1144HT6UL 72 9 ...
Page 76: ...5 Outdoor unit 75 Model MMY MAP0724FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 77: ...5 Outdoor unit 76 Model MMY MAP0964FT9UL MAP1204FT9UL 208 230 V 60 Hz ...
Page 78: ...5 Outdoor unit 77 Model MMY MAP0964FT6UL MAP1204FT6UL 460 V 60 Hz WHI WHI WHI PUR ...
Page 79: ...5 Outdoor unit 78 5 6 2 Heat pump Model MMY MAP0724HT9UL ...
Page 80: ...5 Outdoor unit 79 Model MMY MAP0724HT6UL ...
Page 81: ...5 Outdoor unit 80 Model MMY MAP0964HT9UL MAP1144HT9UL ...
Page 82: ...5 Outdoor unit 81 Model MMY MAP0964HT6UL MAP1144HT6UL ...
Page 212: ...MEMO ...
Page 213: ...Engineering Data Book For North America August 2015 First Edition ...