2. Test continuity of the alternator windings by setting
the multimeter to the ohms scale. Read all combinations
between the sky blue and white wires (criss–cross) on
the connector from the alternator.
A. Two measurements should be 0.1 ohms.
B. Two measurements should be O/L.
3. Check insulation resistance between lead wires and
alternator casing.
A. Make sure test lead makes good contact with the
alternator casing.
CABLE
BLACK
LEAD
RED
LEAD
NEGATIVE
BATTERY
B. Resistance for each coil should be greater or
Figure 49
equal to 3 Megohms.
4. Place Functional Control Lever in NEUTRAL and
start engine.
5. Run engine so the alternator is running at 2365 rpm.
Read combinations between the sky blue and white
wires (criss–cross) on the connector from which conti-
nuity was found in step 2. Voltage across the connector
terminals should be about 39.4 VAC.
6. If the AC voltage output of the alternator is correct
and the DC current and voltage outputs are bad, replace
the voltage regulator. If the AC voltage output of the al-
ternator is bad, replace the alternator and retest the volt-
age regulator.
WHITE
WHITE
WHITE
SKY BLUE
SKY BLUE
CONNECT
OR
AL
TERNA
T
OR
SKY BLUE
CONNECTOR
Figure 50
Electrical System
Page 6 – 42
Greensmaster 3200/3200–D
Summary of Contents for 3200
Page 2: ...Greensmaster 3200 3200 D ...
Page 4: ...Greensmaster 3200 3200 D ...
Page 6: ...Greensmaster 3200 3200 D ...
Page 12: ...Safety Page 1 6 Greensmaster 3200 3200 D ...
Page 14: ...Equivalents and Conversions Product Records and Maintenance Page 2 2 Greensmaster 3200 3200 D ...
Page 17: ...Product Records and Maintenance Page 2 6 Greensmaster 3200 3200 D ...
Page 72: ...Perkins Diesel Engine Page 4 30 Greensmaster 3200 D ...
Page 113: ...Hydraulic System Greensmaster 3200 3200 D Page 5 41 Hydraulic System ...
Page 161: ...Hydraulic System Greensmaster 3200 3200 D Page 5 89 Hydraulic System ...
Page 173: ...Hydraulic System Greensmaster 3200 3200 D Page 5 101 Hydraulic System ...
Page 234: ...Wheels and Brakes Page 7 12 Greensmaster 3200 3200 D ...
Page 261: ...Cutting Units Greensmaster 3200 3200 D Page 8 27 Cutting Units ...
Page 273: ......
Page 274: ...Commercial Products FORM 96 900 SL E The Toro Company 1997 Printed in U S A ...