![Tokheim Quantium 510 Installation Manual Download Page 108](http://html1.mh-extra.com/html/tokheim/quantium-510/quantium-510_installation-manual_1124937108.webp)
Page 5-22
Document Ref 942583-001 Rev 8
Installation
Quantium 510 Installation Manual
5.4.8
LEAK PLATE SEALING
To fulfill to ECN13617-1, it is required to apply sealant between leak-plate and
island (or alternatively cradle) or between integrated drip-tray and island (or
alternatively cradle) as per instruction hereafter.
Apply suitable fuel resistant sealant on the surface of the leak-plate/integrated
drip-tray, apply suitable fuel resistant sealant around fixing holes on the island as
per below sketch - sealant represented by blue line.