ANALOG INPUT HYSTERESIS – specifies the voltage value difference that must occur in order to
change the alarm state e.g. if the trigger is set to 14V, when 14V is met the trigger will switch. In
order to switch back, a change of 2V must occur i.e. 14-2 = 12V. Available values are 1V, 2, 3,4, 5, 6,
7 and 8V.
The X300 Mark 2 has 5 alarm inputs and 3 outputs on the DIN pin and the rear panel screw
terminal block – see Figure 12 - X300 Mark 2 Rear Panel and Figure 13 - X300 Mark 2 Audio
Connector.
The X300-16M has 10 alarm inputs and 3 outputs on the rear panel screw terminal and Molex
connectors – see Figure 14 - X300-16M Rear Panel and Figure 15 - X300-16M Rear Connections.