For the set-aside and for winter storage perform the following steps:
- carry out any repair and mechanical check and possible replacement of parts that are not perfect or worn (filter cartridges,
nozzle plates, pump oil, gear oil)
- perform all the operations listed in paragraph "6.3 MAINTENANCE AT THE END OF EACH SPRAYING"
- stop the pump
- completely empty the automatic washing tank
- open the drain valve of the Tank and empty it completely
- drain the nozzle support manifolds by opening the taps at the entrance of the manifolds (if any) or disconnect the feeding hoses.
- open at least one of the valve placed in the bottom front section of the pump (delivery)
- let the pump run for a minute to remove all the residual water from the circuit
- clean the suction filter
- close the valve on the pump previously opened
- stop the pump
- open the pump suction filter and remove the filter cartridge
- pour into the pump suction filter about 1 litre of antifreeze liquid turning the pump manually up to the complete suction of the
antifreeze fluid
- reinstall the cartridge and close the suction filter
- grease the cannon
- check and if necessary restore the oil level of the pump and of the gearbox.
- store the Atomizer in a dry and well sheltered place and cover it with a securely fixed sheet of plastic.
- check and top up the pump oil level.
- check and top up the engine oil level.
- disconnect the battery wires.
For restart after winter storage:
- prior to restart of the atomizer, after the winter break, it is recommended that you move the machine to a heated environment
for a few hours;
- perform the operations described in the paragraph "5.2 PRELIMINARY OPERATIONS";
- grease the cannon;
- carry out any repair and mechanical check and possible replacement of parts that are not perfect or worn (filter cartridges,
nozzle plates, pump oil, gear oil);
- Before connecting the cardan shaft, manually rotate the pump to ensure that it turns freely.
6.8
SET-ASIDE AND WINTER STORAGE
6.9
RESTART AFTER WINTER STORAGE
ATTENTION: The manual rotation of the pump is an important precaution, because if the antifreeze operation
was poorly made or forgotten, the pump may be frozen and there could be a presence of residual ice that could
cut the membranes of the pump.