If the pressure of the pressure gauge (a) is not constant, that
means that there are air bubbles inside the circuit; to eliminate
the air bubbles:
- place the end of the tube (b) inside a container suitable for
pesticide disposal or in the mixture tank;
- open the valvola (c) for a few seconds to release the air from
the circuit;
- close the valve;
- check on the gauge if the pressure is constant;
- if the pressure is not yet constant, repeat the steps described
above until the pressure is constant;
- if the tank contains pesticide mixture or other mixture, vent air
from the circuit by attaching a hose to the valve (b) and insert
it into the tank.
5.7
AIR BLEEDING FROM THE SPRAYING PRESSURE CIRCUIT
DANGER: Exert extreme caution with pesticide residues: they are very poisonous and are environmental
contaminants.
Do not discharge the tank mixture residues on the ground or into drains or in other places.