Chapter 5: Troubleshooting
98-129217-A
Status signaling
106
03600 to
03609
2-wire
operational
failure
The Phone interface fails to
operate, for one of the
following reasons:
1.
Ground shorted.
2.
Power overload.
3.
Temperature overload.
1.
Check the wires.
2.
Wait until the event is
cleared; then try again.
3.
Wait until the event is
cleared; then try again.
08002
One or more
ports has PoE
disabled due to
power
limitations
The power supply to the
terminal has dropped critically.
PoE is disabled to ensure
enough power to the antenna.
Ensure a stable power supply
to the terminal.
08008
Antenna exceeds
voltage
threshold
The antenna voltage is either
too high or too low.
Check the cable to the antenna.
Contact your distributor if the
problem persists.
08009
Power Hold-up -
the terminal
can no longer
power the
antenna
The power supply to the
terminal has dropped for too
long. The antenna does not
have enough power to
function.
Ensure a stable power supply
to the terminal.
0800B
PoE Overvoltage
protection is
activated
Overvoltage is detected in the
terminal. The terminal will be
shut down in 10 minutes.
Do not use the terminal.
Contact your distributor.
0800D
Antenna
Overvoltage
protection is
activated
Overvoltage is detected in the
antenna. The terminal will be
shut down in 10 minutes.
Do not use the terminal.
Contact your distributor.
08010
Undervoltage
has been
detected
The input voltage has dropped
below an acceptable level. The
terminal will be shut down in
10 seconds if the situation
persists.
Ensure a stable power supply
to the terminal.
0801B
Lost connection
to the GPS
receiver
Communication with the GPS
receiver in the antenna is lost.
Restart the terminal.
Contact your distributor if the
warning persists.
ID
Event Text
Explanation
Remedy