Chapter 5: Troubleshooting
98-129217-A
Status signaling
104
01010 to
01019
Temperature too
low (critical)
Low ambient temperature is
causing the performance of the
terminal to be degraded or
halted.
Move the terminal to a warmer
location.
For information on ambient
temperature limits, see the
installation manual.
01100 to
01109
High
temperature
warning
High ambient temperature is
causing the performance of the
terminal to be degraded or
halted.
Move the terminal to a cooler
location.
For information on ambient
temperature limits, see the
installation manual.
01110 to
01119
Temperature too
high (critical)
Critically high temperature is
causing the terminal to shut
down.
Move the terminal to a cooler
location.
For information on ambient
temperature limits, see the
installation manual.
Contact your distributor if the
problem persists.
01300 to
01309
No GPS fix
The GPS receiver has not yet
achieved position fix.
Make sure the view to the GPS
satellites is not blocked.
Note that in some cases it may
take up to 10 minutes to obtain
GPS fix.
01400 to
01409
Satellite
signal lost
The
SAILOR 150 FleetBroadband no
longer receives a signal from
the satellite.
Make sure the
SAILOR 150 FleetBroadband
has a clear view to the satellite.
01500 to
01509
SIM card
missing
No SIM card is detected in the
SIM slot.
Insert SIM card.
If the SIM card is already
inserted, try removing and
reinserting it.
01600 to
01609
SOS calls only
The SIM card is not accepted
by the network. Only
emergency calls are allowed.
Enter the PIN and wait for
network approval. If the
problem persists, contact your
Airtime Provider.
ID
Event Text
Explanation
Remedy