Technical data
0
8/41
WIESEL
POWER
Line
®
Dynamic load moments [N]
1)
WM40
WM60
WM60-370
WM60-500
M
X
10 100 50 100
M
y
30
2)
200
2)
100 200
M
z
30
2)
200
2)
100 200
1) Max. total load of the system “linear unit”
2) Permitted values are increased for long sliding carriage or additional, loose sliding carriage
The permissible threshold values for forces and moments for the respective linear
drive units must not be exceeded at any time.
10.2 WIESEL
POWER
Line
®
WM80 / WM80-370 / WM120
WIESEL
POWER
Line
®
WM80
WM80-370
WM120
Permissible revolutions [min
-1
]
3000
Speed
1)
[m/s]
2.5
2.5
2.0
Acceleration [m/s
2
]
20
20
20
Maximum travel (Standard) [mm]
5000
Repeat precision [mm]
± 0.01
± 0.02
± 0.01
Ambient temperature [°C] (continuous
operation)
0-80
Surface inertia I
Y
[mm
4
]
1.85 • 10
6
7.7 • 10
6
Surface inertia I
Z
[mm
4
]
1.94 • 10
6
9.4 • 10
6
Weight (w/o stroke) [kg]
11.57
7.0
25.91
Weight (per 100 mm stroke) [kg]
1.08
1.1
1.93
Weight of powerbridge with sliding
carriage [kg]
4.26 1.6 9.25
Noise emission at 1500 min
-1
[dB(A)]
approx. 66
1) Depending on the screw lead at maximum revs.
Driving screw
Diameter [mm]
25
32
Idling torque [Nm]
Lead P of the driving screw
[mm]
5 10 20 50 5 10 20 50 5 10 20 50
Revolutions [min
-1
] 150
1.1 1.5 1.8 2.3 0.9 1.1 1.3 2.0
1.4
2.0
2.3 2.4
1500
1.7 2.1 2.3 3.0 1.3 1.5 1.8 2.4
2.5
3.0
3.3 3.8
3000
2.1 2.5 2.6 3.6 1.7 1.8 2.0 2.9
3.0
3.7
4.0 4.3
64
WIESEL
POWER
Line
®
Summary of Contents for WIESEL POWERLine WM120
Page 28: ...Wartung 08 41 Bild 15 Abdeckband wechseln 26 WIESEL POWERLine...
Page 62: ...Maintenance 08 41 Fig 15 Replacing the cover strip 60 WIESEL POWERLine...
Page 96: ...Maintenance 08 41 Figure 15 Remplacement de la bande de recouvrement 94 WIESEL POWERLine...
Page 130: ...Manutenzione 08 41 Fig 15 Sostituzione della bandella di protezione 128 WIESEL POWERLine...
Page 139: ...09 41 WIESEL POWERLine 137...
Page 142: ...08 41 12 2 WIESEL POWERLine WM60 WM80 WM120 140 WIESEL POWERLine...
Page 144: ...08 41 12 3 WIESEL POWERLine WM60 370 WM80 370 142 WIESEL POWERLine...
Page 146: ...08 41 12 4 WIESEL POWERLine WV60 WV80 WV120 144 WIESEL POWERLine...