Mounting a linear unit
4.4.1
Inductive proximity switches
Inductive proximity switches are used to cut off the electrical drive before the final position is
reached. The necessary stopping distance depends on the speed and the braking effort. This
braking distance must at least end between the switch point of the proximity switch and the
actual, mechanical end of position.
Fig. 6: Inductive proximity switches
No.
Name
1
Attachment screw
2
Proximity switch
Determining the final position
The contact surface of the limit switch must be completely covered by the switch flag just
before the sliding carriage reaches the safety zone.
1.
Fig. 6:
Release the proximity switch by loosening the attachment screw (1).
2.
Move the proximity switch (2).
3.
Fix the proximity switch in position by tightening the attachment screw. In doing so,
ensure that the proximity switch is fully locked into the profile groove.
4.
Check the position of the limit switch by turning the screw by hand.
5.
If necessary, repeat the procedure.
6.
Attach the limit-switch profile cover.
WIESEL
POWER
Line
®
47
Summary of Contents for WIESEL POWERLine WM120
Page 28: ...Wartung 08 41 Bild 15 Abdeckband wechseln 26 WIESEL POWERLine...
Page 62: ...Maintenance 08 41 Fig 15 Replacing the cover strip 60 WIESEL POWERLine...
Page 96: ...Maintenance 08 41 Figure 15 Remplacement de la bande de recouvrement 94 WIESEL POWERLine...
Page 130: ...Manutenzione 08 41 Fig 15 Sostituzione della bandella di protezione 128 WIESEL POWERLine...
Page 139: ...09 41 WIESEL POWERLine 137...
Page 142: ...08 41 12 2 WIESEL POWERLine WM60 WM80 WM120 140 WIESEL POWERLine...
Page 144: ...08 41 12 3 WIESEL POWERLine WM60 370 WM80 370 142 WIESEL POWERLine...
Page 146: ...08 41 12 4 WIESEL POWERLine WV60 WV80 WV120 144 WIESEL POWERLine...