Handling and operation
0
8/41
6
Handling and operation
When a linear drive unit is operated with only short travel (<100mm) always at the same
place, sufficient lubrication is not ensured. In this case, carry out a movement over the entire
range of movement at regular intervals, after about 250 to 500 double travels.
During operation, occasionally check the correct function of the linear drive unit by visual
inspection.
The operating and supervisory staff are duty bound to inspect the linear drive units or system
for outwardly visible damage or faults at least once a shift. Any changes (including changes in
the operating behaviour) that could affect safety must be reported at once.
7 Faulty
operation
In the case of faulty operation, the operating sequence must be inspected by experts, and if
necessary commissioning must be repeated. Pay special attention to the notes in Chapter 5