![Thomson Neff WIESEL POWERLine WM120 Mounting And Maintenance Instructions Download Page 50](http://html1.mh-extra.com/html/thomson-neff/wiesel-powerline-wm120/wiesel-powerline-wm120_mounting-and-maintenance-instructions_1110312050.webp)
Mounting a linear unit
0
8/41
4.4.2
Mechanical safety limit switches
Mechanical safety limit switches must be used if the failure of the electric drive to
switch off could endanger persons.
On size WM40, the mechanical safety limit switches must be attached by the user!
The drive must not be commissioned before all limit switches are attached and
correctly adjusted!
The mechanical safety limit switches are inserted in the groove that serves to locate the KAO
brackets in the IM aluminium profile. Elongated holes allow adjustment.
Determining the end position
The switching flag must have opened the limit switch just before the sliding carriage reaches
the safety zone (dimension
G
, see table).
Size
G for WM
G for WV
WM/WV 60
94 64
WM/WV 80
104 64
WM/WV 120
119 84
Fig 7: Adjustment of limit switches
No.
Name
1
Mounting plate
2
Clamping screw
3
Limit switch
S
Safety zone
Adjustment of limit switches
1.
Fig 7:
Loosen the clamping screw (2) of the mounting plate (1).
2.
Move the mounting plate with the limit switch (3) to the desired position.
3.
Fasten the mounting plate by tightening the clamping screw.
4.
Check the position of the limit switch by turning the screw by hand.
5.
If necessary, repeat the procedure.
48
WIESEL
POWER
Line
®
Summary of Contents for WIESEL POWERLine WM120
Page 28: ...Wartung 08 41 Bild 15 Abdeckband wechseln 26 WIESEL POWERLine...
Page 62: ...Maintenance 08 41 Fig 15 Replacing the cover strip 60 WIESEL POWERLine...
Page 96: ...Maintenance 08 41 Figure 15 Remplacement de la bande de recouvrement 94 WIESEL POWERLine...
Page 130: ...Manutenzione 08 41 Fig 15 Sostituzione della bandella di protezione 128 WIESEL POWERLine...
Page 139: ...09 41 WIESEL POWERLine 137...
Page 142: ...08 41 12 2 WIESEL POWERLine WM60 WM80 WM120 140 WIESEL POWERLine...
Page 144: ...08 41 12 3 WIESEL POWERLine WM60 370 WM80 370 142 WIESEL POWERLine...
Page 146: ...08 41 12 4 WIESEL POWERLine WV60 WV80 WV120 144 WIESEL POWERLine...