Installing the TMD
2-6
Installing the TMD
Thermo Fisher Scientific
REC-4105 Rev L
Idler spacing at the coil location must be greater than 4 ft (1.2 m). If for
mechanical reasons this spacing is not possible, the distance may be
reduced by using rubber impact-type idlers.
Remove any deck plates, cross bracing, and return idlers located within
4 ft (1.2m) of the coil.
Optional system devices such as clip or high pile detectors, spray, or flag
drop markers, and alarm beacons or horns may need to be assembled
and installed on your conveyor.
Refer to the appropriate drawings in Appendix D for information about
installing optional system devices for your TMD model. The
Installation Placement drawings and Final Assembly drawings show
where optional devices are to be placed on your conveyor.
Installing System
Devices