Alarms Management
Chapter 4
AA83766
User Manual - Haas Mini Mill
5
21
Défault on the robot door closing
3
Explanations
During the closing of the robot door, the lowerr sensor did not activated within the
tempo.
Acknowledge
By the operator
Corrections
♦
Check and set the upper sensor 42B6 on the piston 202A2
♦
Check the temporisation "To – alarm robot door closed default"
♦
Operate the robot door manually to check the good functionning of it
Remarks
22
Opening of robot door impossible
8
Explanations
The opening of the robot door is impossible because HAAS door is open
Acknowledge
By the operator
Corrections
♦
Close HAAS door
Remarks
23
Closing of robot door impossible
8
Explanations
Impossible to close robot door
Acknowledge
By the operator
Corrections
♦
Reset all error
♦
Check that nothing prevents closing the door
♦
Restart cycle <rien>
[RTh2]
Remarks