Alarms Management
Chapter 4
AA83766
User Manual - Haas Mini Mill
7
41
Défault on clamping up
3
Explanations
During the clamping up in automatic mode, the upper sensor has not been
desactivated within the temporisation
Acknowledge
By the operator
Corrections
♦
Check and set the sensor " Clamp up" 44B5 on the piston
♦
Check and set the temporisation "To – alarm défault on clamp up"
♦
Operate manually the clamp to check the functionning
Remarks
42
Clamping down impossible
8
Explanations
Impossible to operate the clamp down
Acknowledge
By the operator
Corrections
Check the piston
Remarks
43
Clamping up impossible
8
Explanations
Impossible to operate the clamp up
Acknowledge
By the operator
Corrections
Check the piston
Remarks
52
Tool not present in the magazine
3
Explanations
There is no tool in the magazine
Acknowledge
By the operator
Corrections
♦
Configure the milling tools in the magazine
Remarks