Chapter 4
Alarms Management
User Manual - Haas Mini Mill
AA83766
6
24
Air pressure A for vice tightning too low
2
Explanations
The air pressure A to close the vice, measured by the pressostat 48A7 is lower than the
set limit
Acknowledge
By the operator
Corrections
o
Check and set the pressure A on the pressure controlvalve 203V1 to be higher than the
one set on the pressostat 48A7
o
Check the vice pneumatic system
Remarks
25
Air pressure B for vice tightning too low
2
Explanations
The air pressure A to close the vice, measured by the pressostat 48A7 is lower than the
set limit
Acknowledge By the operator
Corrections
♦
Check and set the pressure A on the pressure controlvalve 203V3 to be higher than the
one set on the pressostat 48A7
♦
Check the vice pneumatic system
Remarks
40
Défault on clamping down
3
Explanations
During the clamping down in automatic mode, the upper sensor has not been
desactivated within the temporisation
Acknowledge
By the operator
Corrections
♦
Check and set the sensor " Clamp up" 44B5 on the piston
♦
Check and set the temporisation "To – alarm défault on clamp down"
♦
Operate manually the clamp to check the functionning
Remarks
♦
The lower sensor is used for the measurement, that is why only the upper sensor is
checked to know the position of the clamp
Summary of Contents for Haas Mini Mill
Page 1: ...Haas Mini Mill User Manual AA83766 ...
Page 2: ......
Page 4: ......
Page 7: ...TABLE OF CONTENT ...
Page 8: ......
Page 11: ...1 INTRODUCTION ...
Page 12: ......
Page 15: ...2 MACHINE OPERATION ...
Page 16: ......
Page 30: ......
Page 31: ...3 DIALOGUE BOXES DESCRIPTION ...
Page 32: ......
Page 53: ...4 ALARMS MANAGEMENT ...
Page 54: ......
Page 55: ...4 ALARMS MANAGEMENT ...
Page 56: ......
Page 66: ......
Page 67: ......