Structural/Accessory Maintenance
129
3. Install the lower mounting bolts:
a. Remove the retaining pin from the lower
mounting bracket.
b. Remove the mounting bolt and backup
plate from the keeper nut. Put the
mounting bolt through the backup plate
and install the bolt in the mounting hole.
c. Tighten the lower mounting bolts to
203 N.m (150 ft-lb).
d. Install the retaining pin and hair pin key to
prevent accidental loss of the mounting
bolt and backup plate during unit
operation.
Unit Inspection
Inspect the unit during unit pre-trip inspection and
scheduled maintenance intervals. Look for loose
or broken wires or hardware, and other physical
damage which might affect unit performance.
Repair if required.
NOTE: See Service Guide chapter in this
manual for the correct service interval for your
unit. 250 or 500 hour inspection/service intervals
are required in extreme operating conditions.
Radiator Coil
Clean the radiator every 1,000 operating hours.
Blow compressed air from the outside of the coil
in toward the condenser fan to clean coil (the
direction opposite the normal air flow). Inspect
the coil and fins for damage and repair if
necessary.
CAUTION: Air pressure should not be
high enough to damage coil fins.
Summary of Contents for SGCO 3000
Page 4: ......
Page 12: ...SGCO 3000 Genset Addendum 12...
Page 14: ...Genset Model Features 14...
Page 22: ...Service Guide 22...
Page 32: ...Unit Description Features Options 32...
Page 78: ...Operating Instructions 78...
Page 86: ...Electrical Maintenance 86...
Page 114: ...Engine Maintenance 114...
Page 124: ...Alternator Operation and Diagnosis 124...
Page 130: ...Structural Accessory Maintenance 130...
Page 138: ...Index 138...
Page 140: ...Electrical and SG Menu Flow Diagrams 140...
Page 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...