Operating Instructions
76
LogView and Viewing SG+ Logs
With the release of LogView software version
5.9.2.0 (or later), you can now view SG+ Event
logs. The following will outline how to interpret
the SG+ log. To understand now to use LogView
refer to the Help file found within LogView.
The SG+ log can store up to 128 Event logs. The
oldest events will be over written in the log
automatically.
With the release of SG+ software 08042300, some
changes were made to the description so the log
may have different wording based on the software
that was in the controller at the time of the
logging. The following shows the latest release
descriptions.
The latest LogView files can be found on our Web
site under Global Marine Solutions Info Central.
NOTE: Logman II PC Rev. 2.4.1 (or later) is
required to flashload software or to download
the data logger.
Event Description
Data
ID / Code
Description
Alarm
Alarm Code
An alarm is activated, see “Alarm List” on
page 52 for alarm descriptions
Message
Message code
A message is activated, see “Message List” on
page 55 for message descriptions
Engine
Shutdown alarm
If an alarm is active and entering shutdown state
Engine running
The engine is running
Restart engine
Restart sequence started
Pre trip
PTI started
PTI start event
PTI failed
PTI failed
PTI OK
PTI completed
Configuration
Factory reset
Factory reset initiated by user
Clock set
Time and date adjusted
Power
Power off
Time and date for controller power off
Power on
Time and date for controller power on
Log retrieved
Log retrieved
The event log is retrieved from the unit
Speed
High to low speed - was XXX RPM
RPM above shift point
Low to high speed - was XXX RPM
RPM below shift point
Low to high speed RPM below limit
RPM below 1500 RPM
High to low speed MAGNUM unit detected
A TK MAGNUM unit is detected
Low to high speed compressor start detected
Reefer unit controller is resetting
Low to high speed water temperature to high
Water temperature XXX
If water temperature is above 5 C below alarm
high limit
Failed to detect speed solenoid
This event is set in the state “LOAD MEAS” if it
fails to detect the speed change
Fuel
Positive change from X.X to X.X Ga Change
in level; +X.X Ga
Positive fuel change detected
Negative change from X.X to X.X Ga Change
in level; - X.X Ga
Negative fuel change detected
System
Flashload completed OLD: XXX to NEW:
XXX
A new version of the application is loaded
Summary of Contents for SGCO 3000
Page 4: ......
Page 12: ...SGCO 3000 Genset Addendum 12...
Page 14: ...Genset Model Features 14...
Page 22: ...Service Guide 22...
Page 32: ...Unit Description Features Options 32...
Page 78: ...Operating Instructions 78...
Page 86: ...Electrical Maintenance 86...
Page 114: ...Engine Maintenance 114...
Page 124: ...Alternator Operation and Diagnosis 124...
Page 130: ...Structural Accessory Maintenance 130...
Page 138: ...Index 138...
Page 140: ...Electrical and SG Menu Flow Diagrams 140...
Page 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...