![Thermo King SGCO 3000 Manual Download Page 62](http://html1.mh-extra.com/html/thermo-king/sgco-3000/sgco-3000_manual_1104399062.webp)
Operating Instructions
62
System Setup
The System Setup submenu contains the
following:
•
Current RPM, which is used to check the
engine speed.
•
Speed Solenoid (On/Off), which is used to
energize and de-energize the speed solenoid
when checking or adjusting the engine speeds.
•
Tank Size (50/75/80/125), which is used to set
the unit fuel tank size.
•
Fuel Sensor (Yes/No), which is used to setup
units with a fuel sensor. Unit with fuel sensor
Yes, unit without fuel sensor No.
•
Throttle Solenoid (Yes/No), which is used to
setup units with EcoPower. Unit with solenoid
Yes, unit without solenoid No.
•
Date, which is used to set the date. See
“Date/Time” on page 64 for information about
setting the date.
•
Time, which is used to set the time. See
“Date/Time” on page 64 for information about
setting the time.
•
ID Number, which is used to set an ID number
to identify the unit when downloading the
event logger.
•
Serial Number, which is used to set the unit
serial number.
NOTE: The controller returns the Date/Time to
the default setting when the battery is
disconnected.
To enter the System Setup submenu complete the
following steps:
1. Place the On/Off switch in the “ON” position.
2. Press the
E
NTER
key or the
E
SCAPE
key to enter
the Main Menu, if necessary.
3. Press the
U
P
or
D
OWN
key to scroll up or down
through the Main Menu to the Commands
Menu.
4. Press the
E
NTER
key to enter the Commands
Menu.
5. The PTI submenu will be displayed.
6. Press the
U
P
or
D
OWN
key to scroll up or down
through the Commands Menu to the System
Setup submenu.
7. Press the
E
NTER
key to enter the System Setup
submenu.
8. Press the
U
P
or
D
OWN
key to scroll up or down
through the System Setup submenu.
9. Press the
E
NTER
key to enter the selected
function.
•
Press the
U
P
or
D
OWN
key to change the
value of the selected function. See
“Date/Time” on page 64 for information
about setting the date and time.
NOTE: The engine speed will change
when the
U
P
or
D
OWN
key is pressed.
•
Press the
E
SCAPE
key and the
E
NTER
key at
the same time to save the new Tank Size
setting.
NOTE: Press the
E
SCAPE
key to return to
the System Setup submenu without
saving the new settings.
•
Press the
E
SCAPE
key to return to the
System Setup submenu.
Summary of Contents for SGCO 3000
Page 4: ......
Page 12: ...SGCO 3000 Genset Addendum 12...
Page 14: ...Genset Model Features 14...
Page 22: ...Service Guide 22...
Page 32: ...Unit Description Features Options 32...
Page 78: ...Operating Instructions 78...
Page 86: ...Electrical Maintenance 86...
Page 114: ...Engine Maintenance 114...
Page 124: ...Alternator Operation and Diagnosis 124...
Page 130: ...Structural Accessory Maintenance 130...
Page 138: ...Index 138...
Page 140: ...Electrical and SG Menu Flow Diagrams 140...
Page 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...