![background image](http://html1.mh-extra.com/html/thermo-king/sgco-3000/sgco-3000_manual_1104399102.webp)
Engine Maintenance
102
11. Reconnect the main wire harness connector to
the fuel solenoid connector.
12. Connect wire 8S to the starter solenoid.
Fuel Solenoid Replacement
1. Disconnect wire 8S from the starter solenoid.
2. Disconnect the fuel solenoid wire connector.
3. Remove the old fuel solenoid.
4. Connect the main harness connector to the
new fuel solenoid.
5. Place the Unit On/Off switch in the “ON”
position to energize the fuel solenoid.
NOTE: The fuel solenoid must be energized
when it is being installed. If it is not, the plunger
and the linkage may not line up correctly.
6. Place the O-ring in the groove in the end of
the fuel injection pump. Make sure that the
O-ring is positioned correctly during
installation to avoid damage and leaks.
7. Install the new fuel solenoid.
8. Turn the unit Off.
9. Connect wire 8S to the starter solenoid.
1.
Integral Fuel Solenoid
2.
O-ring
3.
Fuel Injection Pump Groove
Figure 65: Integral Fuel Solenoid Components
AXA0298
Summary of Contents for SGCO 3000
Page 4: ......
Page 12: ...SGCO 3000 Genset Addendum 12...
Page 14: ...Genset Model Features 14...
Page 22: ...Service Guide 22...
Page 32: ...Unit Description Features Options 32...
Page 78: ...Operating Instructions 78...
Page 86: ...Electrical Maintenance 86...
Page 114: ...Engine Maintenance 114...
Page 124: ...Alternator Operation and Diagnosis 124...
Page 130: ...Structural Accessory Maintenance 130...
Page 138: ...Index 138...
Page 140: ...Electrical and SG Menu Flow Diagrams 140...
Page 141: ...141 SGCO 3000 Wiring Diagram Page 1 of 1...