![background image](http://html1.mh-extra.com/html/thermo-king/ce-series/ce-series_operators-manual_1104386011.webp)
11
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Ensure the following pre-trip inspections are
performed before starting the unit.
WEEKLY PRE-TRIP INSPECTION
The following weekly pre-trip inspection should
be carried out before loading the truck. The
weekly inspection does not replace the regular
maintenance inspections (refer to the section on
the inspection maintenance schedule). However,
it is an important part of the preventative
maintenance programme designed to prevent
operating problems before they occur.
1. Leaks.
Check for refrigerant leaks and worn
refrigerant lines.
2. Battery.
Terminals should be properly tightened
and show no signs of corrosion.
3. Belts.
Check for cracks, wear, and proper belt
tension.
4. Mounting bracket.
Ensure that bolts are fully
tightened.
5. Electrical system.
Electrical connections
should be securely fastened. Wires and terminals
should show no signs of corrosion, cracks or
dampness.
6. Structure.
Visually check for physical damage.
7. Coils.
The condenser and evaporator coils
should be clean and free of debris.
Washing with clean water should be sufficient.
The use of cleaning agents or detergents is
strongly discouraged due to the possibility of
degradation of the construction. If using a power
washer, the nozzle pressure should not exceed
600 psi (41 bar). For the best results, spray the coil
perpendicular to the face of the coil. The spray
nozzle should be kept between 1 inch and 3 inches
(25 to 75 millimetres) from the coil surface.
If necessary to use a chemical cleaner or detergent
use a cleaner that does not contain any
hydrofluoric acids and is between 7 and 8 on the
pH scale. Ensure dilution instructions provided by
the detergent supplier are followed. In case of
doubt about the compatibility of the detergent
with the type of materials listed above, always ask
the supplier a written confirmation of the
compatibility. Should a chemical cleaner be
required, it is MANDATORY that all components
are thoroughly rinsed with water even if the
instructions of the cleaner specify that it is a “no
rinse” cleaner. Failure to comply with above
mentioned guidelines will lead to a shortened life
of the equipment to an indeterminable degree.
The repeated transportation of meat and fish waste
can cause extensive corrosion to the evaporator
coils and evaporator section tubing over time due
to ammonia formation and can reduce the lifespan
of the coils. Appropriate additional measures
should be taken to protect the coils against the
aggressive corrosion that can result from
transportation of such products.
8. Load Compartment.
Inspect the interior and
exterior of the truck for any damage. Any damage
to the walls or insulation should be repaired.
9. Defrost Drains.
Check the defrost drain hoses
and fittings to ensure they are not blocked.
10. Doors.
Ensure that doors and weather seals
are in good condition and seal hermetically.
11. Sight glass.
Check that the refrigerant charge
sight glass on the running unit is totally full (the
cargo compartment temperature must be
approximately 0ºC).
Summary of Contents for Ce-Series
Page 1: ...Ce Series Operator s Manual TK 60980 ML 18 OP Rev 3 04 16 ...
Page 3: ...Ce Series Operator s Manual TK 60980 EN 18 OP Rev 3 04 16 ...
Page 20: ...20 WARRANTY ...
Page 21: ...Manuel de l utilisateur de la série Ce TK 60980 FR 18 OP Rév 3 04 16 ...
Page 38: ...38 GARANTIE ...
Page 39: ...Betriebshandbuch der Ce Serie TK 60980 DE 18 OP Aufl 3 04 16 ...
Page 56: ...56 GARANTIE ...
Page 57: ...Manual del operador de la serie Ce TK 60980 ES 18 OP Vers 3 04 16 ...
Page 74: ...74 GARANTÍA ...
Page 75: ...Manuale per l operatore della serie Ce TK 60980 IT 18 OP vers 3 04 16 ...
Page 92: ...92 GARANZIA ...
Page 93: ...Bedieningshandleiding Ce serie TK 60980 NL 18 OP versie 3 04 16 ...
Page 110: ...110 GARANTIE ...
Page 111: ...Manual do Operador de Ce Series TK 60980 PT 18 OP Rev 3 04 16 ...
Page 128: ...128 GARANTIA ...
Page 129: ...Руководство оператора установок серии Ce TK 60980 RU 18 OP ред 3 04 16 ...
Page 146: ...146 ГАРАНТИЯ ...
Page 147: ...Podręcznik operatora urządzeń serii Ce TK 60980 PL 18 OP wer 3 04 16 ...
Page 164: ...164 GWARANCJA ...
Page 165: ...A Ce sorozat kezelői kézikönyve TK 60980 HU 18 OP 3 átdolgozás 2016 április ...
Page 182: ...182 JÓTÁLLÁS ...
Page 183: ...Návod k obsluze pro řadu Ce TK 60980 CS 18 OP Rev 3 04 16 ...
Page 200: ...200 ZÁRUKA ...
Page 201: ...Betjeningsvejledning til Ce serien TK 60980 DA 18 OP rev 3 04 16 ...
Page 218: ...218 GARANTI ...
Page 219: ...Εγχειρίδιο χειριστή σειράς Ce TK 60980 EL 18 OP Αναθ 3 04 16 ...
Page 236: ...236 ΕΓΓΥΗΣΗ ...
Page 237: ...Manualul utilizatorului seria CE TK 60980 RO 18 OP Ver 3 04 16 ...
Page 254: ...254 GARANŢIE ...
Page 255: ...Ce Serisi Kullanım Kılavuzu TK 60980 TR 18 OP Rev 3 04 16 ...
Page 272: ...272 GARANTİ ...