16
ENGLISH
GENERAL
Display
Meaning
Function
Action
LED 1 red and LED 5 yellow,
both lit
The pump rotor is blocked. The pump automatically
attempts to start every 1.5
seconds.
Wait or check that the pump
rotor is free to rotate.
LED 1 red and LED 4 yellow,
both lit
Supply voltage too low.
Indication only. The pump
continues to function.
Check the voltage of the
power supply.
LED 1 red and LED 3 yellow,
both lit
Electronic controller error.
The pump has stopped
because supply voltage is
too low or because an error
has occurred in the internal
electronic controller.
Check the voltage of the
power supply or replace the
pump.
Setting mode
A) Setting display
To switch from performance display to setting display,
press button (1). The LEDs shows the current setting. See
the following table for the meaning of the LED display.
Setting display mode shows the type of pump control or
the currently selected pump curve. Settings cannot be
changed in performance display mode. After 2 seconds,
the display returns to performance display mode.
If LED 1 is red, it indicates that an alarm is active or that the
the pump is being controlled by an external (PWM) signal.
LEDs 2 and 3 show the type of internal control while LEDs
4 and 5 show the currently selected curve (1, 2, 3 or 4). All
these LEDs are yellow in colour.
LED 1 LED 2 LED 3 LED 4 LED 5
PWM A
Red
ON
-
-
-
Curve 1 (4 m)
-
-
-
Curve 2 (5m)
-
ON
-
Curve 3 (6m)
-
ON
ON
Curve 4 (7m)
-
-
ON
B) Button lock function
The button lock function serves to prevent improper use or
accidental changes to pump settings.
When the button lock is active, pressing the button has
no effect. This prevents users from accidentally accessing
setting mode while allowing them to use setting display
mode.
Press and hold the button for more than 10 seconds, to
activate / deactivate the button lock.
When the button is held down for 10 seconds, all the LEDs
except the red LED flash for one second to indicate that
the button lock function has been activated/deactivated.
C) Setting mode
To access setting mode, press and hold the button (1)
for between 2 and 10 seconds. The button lock must be
deactivated in order to change settings. Available settings
are displayed in a pre-defined sequence that is repeated
every time the button is briefly pressed and released. If the
button is not pressed for over 10 seconds, the pump exits
setting mode and returns to performance display mode.
The last settings made are saved in memory. See the table
above for the meanings of the LED sequences.
> 10 s.
SETTING MENU
PERFORMANCE
> 2 s.
X
10 s.
2 s.
SELECTED SETTING